Voltage Repeater KFD2-VR4-Ex1.26
pepperl-fuchs
1-channel isolated barrier
24 V DC supply (Power Rail)
Voltage input 0 V … -20 V
Vibration sensor inputs
Voltage/current field supply
Voltage output 0 V … -20 V
Up to SIL 2 acc. to IEC 61508
Voltage Repeater KFD2-VR4-Ex1.26
pepperl-fuchs
General specifications | ||
---|---|---|
Signal type | Analog input | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 2 | |
Supply | ||
Connection | Power Rail or terminals 11+, 12- | |
Rated voltage | 19 … 30 V DC | |
Ripple | within the supply tolerance | |
Power dissipation | ≤ 1.2 W | |
Power consumption | ≤ 1.6 W | |
Input | ||
Connection side | field side | |
Connection | terminals 4 (common), 1, 3 and 5 (supply -), 2 and 6 (signal -) | |
Input resistance | 10 kΩ terminals 4 (common), 6-/2- | |
Output rated operating current | terminals 4 (common), 5-: > 10 mA at -21 V or > 20 mA at -18 V terminals 4 (common), 1-: 5.3 mA ±0.4 mA at -10 V terminals 4 (common), 3-: 3.6 mA ±0.7 mA at -10 V, 20 °C (68 °F) |
|
Transmission range | -20 … 0 V | |
Output | ||
Connection side | control side | |
Connection | terminals 7-, 8+ | |
Voltage | -20 … 0 V | |
Load | ≥ 9 kΩ (3-wire sensor), ≥ 2 kΩ (2-wire sensor) | |
Output resistance | 24 Ω typ., 27 Ω maximum Since this is much less than the end-to-end resistance of a zener barrier, it may be necessary to specify a monitor intended for use without a barrier. Please follow the advice of the monitor manufacturer. |
|
Transfer characteristics | ||
Cut-off frequency | 10 kHz (-0,1 dB) 20 kHz (-1 dB) |
|
Deviation | DC transfer error (with 10 kΩ load) < 10mV | |
After calibration | additional error with AC superimposed is ±5 mV at 20 °C (68 °F) at any point within the span, provided that the alternating component of the input voltage is not excessive, e. g. – square waves (0 … 20 kHz): 5 Vpp – sine waves (0 … 20 kHz): the full span of 20 Vpp (= 100 g peak acceleration at 100 mV/g) is acceptable. |
|
Influence of ambient temperature | (< 100 ppm of span)/K at any point within the span | |
Time delay relative to input | 7.1 ±0.3 µs | |
Ripple | in 200 kHz bandwidth < 20 mVrms in 20 kHz bandwidth < 3 mVrms |
|
Galvanic isolation | ||
Output/power supply | functional insulation, rated insulation voltage 50 V AC | |
Indicators/settings | ||
Display elements | LED | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Electromagnetic compatibility | NE 21:2017 EN IEC 61326-3-2:2018 |
|
Degree of protection | IEC 60529 | |
Protection against electrical shock | UL 61010-1 | |
Ambient conditions | ||
Ambient temperature | -20 … 60 °C (-4 … 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Mass | approx. 125 g | |
Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EU-type examination certificate | BAS 02 ATEX 7206 | |
Marking | II (1)GD, [Ex ia Ga] IIC, [Ex ia Da] IIIC, (-20 °C ≤ Tamb ≤ 60 °C) [circuit(s) in zone 0/1/2] | |
Input | Ex ia Ga, Ex ia Da | |
Voltage | -26.4 V | |
Current | 90 mA | |
Power | 570 mW | |
Supply | ||
Maximum safe voltage | 253 V (Attention! The rated voltage can be lower.) | |
Output | ||
Maximum safe voltage | 253 V (Attention! The rated voltage is lower.) | |
EU-type examination certificate | DMT 01 ATEX E 133 | |
Marking | I (M1) [Ex ia] I | |
Certificate | TÜV 99 ATEX 1499 X | |
Marking | II 3G Ex nA II T4 [device in zone 2] | |
Galvanic isolation | ||
Input/Output | safe galvanic isolation acc. to IEC 60079-11, voltage peak value 375 V | |
Input/power supply | safe galvanic isolation acc. to IEC 60079-11, voltage peak value 375 V | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 , EN 50303:2000 | |
International approvals | ||
UL approval | ||
Control drawing | 116-0316 (cULus) | |
IECEx approval | ||
IECEx certificate | IECEx BAS 05.0078 IECEx BAS 10.0085X |
|
IECEx marking | [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I Ex nA II T4 Gc |
|
General information | ||
Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Optional accessories | – power feed module KFD2-EB2(.R4A.B)(.SP) – universal power rail UPR-03(-M)(-S) – profile rail K-DUCT-BU(-UPR-03) |
Voltage Repeater KFD2-VR4-Ex1.26
pepperl-fuchs
If you need a specific Voltage Repeater KFD2-VR4-Ex1.26 firmware or series, then we probably have it. Please call or email us your request.
call: +982188856017
Email: info@hermestrading.ir
شركت هرمس نیلگون مایا با هدف ارتقاء سطح كيفي تجهيزات فني و آزمايشگاهی، نفت، گاز، پتروشیمی، دانشگاهی، عمرانی و همچنين تامین تجهیزات روز دنيا به كشور ايران وارد اين عرصه گرديده.
اين شركت با اعتماد قابل تقدير شما عزيزان توانسته است در مدت زماني كوتاه با كسب موفقيت های چشمگير، نامی قابل اعتماد در زمينه تامین تجهيزات نوين و پيشرفته فنی و آزمايشگاهی در سراسر كشور داشته باشد.
ما با حضوری فعال و کم نظیر سعی نموده ایم تا با مشاوره فنی، معادل و بهینه سازی تجهیزات مورد نیاز، انبار موجودی و امکان تحویل فوری، دفاتر برون مرزی در اروپا و آسیا و عاملیت فروش برند های معتبر و فعال در صنعت کشور، موجبات تامین آسوده، کم هزینه و ایمن را برای کاربران خود فراهم آوریم و گامي مهم در زمينه تامین کالا و ارائه تجهيزات پيشرفته در صنعت نفت، گاز، پتروشیمی برداریم. با ما در تماس باشید.
Voltage Repeater KFD2-VR4-Ex1.26
pepperl-fuchs
شرکت هرمس نیلگون مایا –
با ما در تماس باشید صفحه تماس با ما ——> اینجا کلیک کنید